Check information about Integrations infrastructure

Sensedia API Gateway and Sensedia Integrations can be acquired by the same customer. In this case, both products are provisioned in the same Sensedia VPC. To provide an optimized experience, when a customer chooses to establish private connectivity with the Sensedia VPC, both products have access to the same network where the private backends are located.

In Sensedia Integrations, for each integration created, at least 7 IPs from the VPC are consumed by Sensedia infrastructure, but this value can increase as integrations scale horizontally.

There will be considerable IPv4 consumption in the VPC:

  • Due to sharing the same VPC.
  • Taking into account scenarios of high consumption and scalability of Sensedia API Gateway APIs and/or each Sensedia Integrations integration.

Therefore, we recommend at least the use of networks with /21 mask, but ideally networks with /20 mask should be used. The customer should consider this when establishing private connectivity to avoid IP overlap between the local network and the Sensedia VPC.